Air Intake
Room air is drawn through a pre-filter, which captures larger dust particles before the air reaches the primary filtration stage.

AIRTEC CAPABILITY / AIR PRESSURE CONTROL
Positive Pressure Module Manufacturer and Negative Pressure Module Manufacturer for controlled environments across Maharashtra and India.
PRESSURE MODULES / PUNE
When searching for a reliable Pressure Module Manufacturer in Maharashtra, controlling contamination and maintaining the correct air pressure balance are important considerations.
PRESSURE CONTROL IN PRACTICE
Our pressure modules combine compact engineering, HEPA filtration and controlled air movement to support dependable room-pressure performance.


PRESSURE CONTROL ENGINEERING
Getting the airflow direction right can be critical for controlled environments such as hospital operation theatres, pharmaceutical cleanrooms, isolation areas, and industrial sterile zones.
Airtec Solutions is a Positive Pressure Module Manufacturer as well as a Negative Pressure Module Manufacturer based in Pune. Our compact air-handling units help maintain pressure differentials across controlled areas without necessarily installing a complete centralized air-handling system.
We manufacture pressure modules for hospitals, pharmaceutical industries, diagnostic laboratories, research facilities, and industrial cleanrooms across Maharashtra.
Discuss your pressure module ↗SYSTEM WORKING PRINCIPLE
A pressure module is a compact, self-contained air filtration and air-supply or extraction unit designed to be installed into a wall or window opening. Depending on the configuration, it can help regulate room pressure and filter airborne particles in cleanrooms, operation theatres, isolation areas, and other controlled environments.
Room air is drawn through a pre-filter, which captures larger dust particles before the air reaches the primary filtration stage.
A blower assembly moves air through the pressure module at a controlled airflow rate.
Air passes through a HEPA filter where fine airborne particles are captured. Filtered air is then supplied to the controlled area in positive-pressure applications.
Positive modules supply filtered air into the room, while negative modules extract air to help reduce contaminated-air movement into adjacent spaces.
Suitable cooling or air-conditioning arrangements can be integrated where the application requires additional environmental control.
CONFIGURATION GUIDE
Choosing between a positive pressure module and a negative pressure module depends primarily on whether the controlled environment needs to minimize contaminant entry or minimize contaminant escape.
| Parameter | Positive Pressure Module | Negative Pressure Module |
|---|---|---|
| Airflow Direction | Pushes filtered air into the room | Extracts air from the room |
| Pressure Relative to Surroundings | Higher than adjacent areas | Lower than adjacent areas |
| Primary Purpose | Helps prevent external contaminants from entering | Helps contain contaminants within the controlled area |
| Typical Applications | Operation theatres, ICUs, pharmaceutical cleanrooms, sterile areas | Isolation rooms, quarantine areas, infectious-disease areas, containment environments |
| Contamination Risk Managed | Entry of airborne particles and contaminants | Escape of airborne particles and contaminants |
| Filtration | Pre-filter + HEPA filter, according to configuration | Pre-filter + HEPA filter, according to configuration |
| Common Industries | Hospitals, pharmaceutical manufacturing, electronics and precision cleanrooms | Hospitals, research facilities, biosafety and containment applications |
| Pressure Role | Maintains higher room pressure | Maintains lower room pressure |
| Automation | Automatic or manual, as required | Automatic or manual, as required |
| Manufacturer | Airtec Solutions, Pune, Maharashtra | Airtec Solutions, Pune, Maharashtra |
Pressure modules can be designed for controlled environments requiring specified cleanliness classifications. Final room classification depends on the complete room design, airflow, filtration, air changes, pressure cascade, construction, monitoring, and validation.
TECHNICAL PROFILE
| Parameter | Details |
|---|---|
| Brand | Airtec Solutions |
| Material | GI powder-coated construction |
| Standard Colour | RAL 9002 |
| Filtration | Pre-filter + HEPA filter, as required |
| Automation Grade | Automatic or manual, as required |
| Voltage | 230V, 50Hz, single phase |
| Airflow Capacity | Customizable according to room size and air-change requirements |
| Country of Origin | Made in India |
| Corrosion Resistance | Powder-coated construction provides resistance to normal environmental exposure |
BENEFITS & FEATURES
HEPA-filtered airflow helps reduce airborne particulate contamination in controlled environments.
Directional airflow and pressure differentials can help reduce unwanted airflow between adjacent zones.
The compact form factor can be installed into suitable wall or window openings, reducing the need for extensive ducting in applicable installations.
GI powder-coated construction provides a durable enclosure suitable for controlled-environment applications.
Properly selected blower and filtration configurations help maintain the required airflow and pressure conditions.
Airflow capacity, filtration configuration, dimensions, and automation can be customized according to the application and room requirements.
APPLICATIONS
WHY AIRTEC SOLUTIONS
As a manufacturer based in Bhosari, Pune, Maharashtra, Airtec Solutions supports pressure-module projects from configuration through installation and service.
CUSTOM PRESSURE MODULES
Planning a hospital, pharmaceutical, laboratory, or industrial cleanroom project in Maharashtra? Share your room size, required air-change rate, pressure requirement, and application details with our team to discuss a suitable configuration and customized quotation.
01Pressure module configuration and selection
02Installation, commissioning and service support
03Related cleanroom equipment for complete setups
FAQ
A positive pressure module supplies filtered air into a room to maintain a higher pressure relative to surrounding areas. This helps reduce the entry of unfiltered air and is commonly used in environments such as operation theatres and controlled clean areas. A negative pressure module extracts air from a room to maintain lower pressure relative to surrounding areas. This helps reduce the movement of potentially contaminated air into adjacent spaces and is commonly used for isolation and containment applications.
Pressure modules are used in applications where controlled airflow, filtration, and pressure differentials are important. These include hospitals, pharmaceutical manufacturing facilities, diagnostic and research laboratories, isolation areas, containment environments, and electronics or precision manufacturing cleanrooms.
Yes. Pressure modules can be customized according to the application and room requirements. Parameters such as airflow capacity, filter configuration, physical dimensions, and automation can be selected based on factors including room size, air-change requirements, pressure requirements, and intended use.
Airtec Solutions pressure modules can be configured with HEPA filtration according to the application requirements. Where a HEPA filter rated at 99.97% efficiency is specified, that rating refers to the filter's performance under the applicable test conditions. The appropriate filter configuration should be selected based on the project's cleanliness, airflow, and filtration requirements.
Yes. Airtec Solutions is based in Pune, Maharashtra, and supplies pressure modules for projects across Maharashtra. Depending on the project, installation, commissioning, and maintenance support can also be provided in Pune, Mumbai, Nashik, and Chhatrapati Sambhajinagar.